StorageTek 9840 User Manual

Page 185

Advertising
background image

95741

Sixth Edition

6-29

SCSI Change Configuration Menu

VolSafe Selection Submenu

VolSafe Y

VolSafe N

Defaults to last saved selection.

When

VolSafe Y

is selected, a

password (Contact StorageTek
Technical Support) must also be
entered before VolSafe is enabled.

When

VolSafe N

is selected,

VolSafe is disabled.

1. Press

Menu

to bypass, or

2. Press

Select

to toggle option;

then, press

Menu

to set.

3. If applicable, press

Select

to start

password entry. The left-most
character begins flashing.

4. Press

Select

to increment until

desired character is displayed,
then press

Menu

to set.

5. Repeat step 4 for each character.

6. Press

Menu

to advance to the next

submenu; or, press

Select

to restart.

Note: Manufacturing ships drive with the

VolSafe N

option

selected.

Full Code Load Submenu

FullCode Y

FullCode N

Defaults to last saved selection.

When

FullCode Y

is selected,

all drive code images are
downloaded to the EEPROM. This
enables the drive to be used to
create a code tape with all images
which then could be used to
update other drives.

When

FullCode N

is selected,

only the specific code image for
the drive is downloaded to
EEPROM. This option allows
more EEPROM space for dumps
and event logs, but disables the
drive from creating code tapes.

1. Press

Menu

to bypass, or

2. Press

Select

to toggle option;

then, press

Menu

to set, and

advance to the next submenu.

Note: Manufacturing ships drive with only one code image, and

FullCode N

selected.

CodCrFail3

displays if you try to make a code tape from a drive with only one

image loaded. (Code release level 1.30.109 and up, displays

CHK A738

.)

To enable a drive to create code tapes, select

FullCode Y

, and load the desired

code release level from a valid source.

Table 6-2. Menu Table—SCSI Configuration (Continued)

Options

Notes

Procedure