StorageTek 9840 User Manual

Page 145

Advertising
background image

95741

Sixth Edition

5-29

Error and Recovery

4E23

CSL encountered an error during an
unload.

1. Check the CSL for any error

condition.

2. Remove the cartridge.

3. Press the

Start

switch once.

Note:

LOAD 4E23

will

display until you press
the

Load

or

Start

switch.

4E2D

SCSI load command failed due to
the CSL no longer in the System
mode. The mode was changed
during the load.

Return CSL to System Mode.

4E31

SCSI load command failed due to
the CSL no longer in the System
mode. The mode was changed
during the load. This error occurs
immediately after a cleaning or
dump cartridge has just been
unloaded.

Return CSL to System Mode.

4E34

SCSI load command failed due to
no cartridge being available to load.
This error only occurs immediately
after a cleaning or dump cartridge
has just been unloaded and the CSL
is in the Automatic mode.

Load a cartridge.

Table 5-6. CSL FSCs

FSC

Malfunction

Fix