Manual mode, Unload, Place csl in manual mode – StorageTek 9840 User Manual

Page 135: Manual mode -19, Unload -19 place csl in manual mode -19

Advertising
background image

95741

Sixth Edition

5-19

Modes of Operation

4. Press the

Start

switch.

5. Unload the output bin when the job is complete or as necessary.

Manual Mode

In manual mode, the operator has complete control over CSL and drive
operation. While the CSL is in manual mode:

You may wait for a cartridge mount request and then mount a cartridge.

You may receive requests for multiple cartridge mounts and load the
requested volumes into the input tray.

You may remove individual cartridges as they are ejected from the feed
channel or wait until the output bin is full before removing them.

Note: In Manual mode, however, you must press the

Start

switch each time to

load a cartridge into the drive.

Refer to

“Priority Mount Mode” on page 5-20

to physically mount a

priority cartridge directly into the CSL.

Unload

Upon receiving an unload command from the drive, the CSL acts identically to
the unload in the system mode.

After the unload is successfully completed the CSL pauses until the

Start

switch

is pressed. Pressing the

Start

switch loads the next available cartridge. The CSL

sequences as follows:

If the output bin is not full, the cartridge is placed into the output bin.

If the output bin is full, the cartridge remains in the feed channel, and the

operator

indicator blinks until the cartridge is removed from the output bin

and the

Start

switch is pressed.

Note: Refer to

“Cartridge Removal from Feed Channel” on page 5-22

to

remove a priority mounted cartridge from the feed channel.

If a mount has been pre-queued then, if possible, the next cartridge is
mounted with only one cartridge shift operation.

Place CSL in Manual Mode

1. Press the

Autoload Mode

switch until the green

manual

indicator illuminates.

2. Press the

Start

switch to set the Manual mode.

3. When a mount message appears on the operator panel or system console,

place the requested volumes in the input bin.

4. Press the

Start

switch.

5. Unload the output bin when necessary.