1. Remove the incorrectly loaded cartridge:

a. Press down on the cartridge stop mechanism (

Figure 5-18 on

page 5-24

).

b. Grasp the cartridge and pull it from the feed channel.

2. Clear the CSL error.

a. Press the

Start

switch (

Figure 5-17 on page 5-23

) to clear the solid

operator

indicator.

b. After the

Start

switch is pressed, the

operator

indicator blinks and the

operator display still shows

LOAD 4E04

until a successful load or you

press the

Unload

switch (

Figure 5-18 on page 5-24

) to clear the display.

3. Ensure all remaining cartridges to be loaded are placed within the input bin

correctly (cartridge reels to the right).

4. The CSL is now ready for normal operations.