Port communication numbers, Tablea3 port communicationnumbers, Virtualization engine service codes – Sun Microsystems 6900 User Manual

Page 180: Sun proprietary/confidential: internal use only

Advertising
background image

160

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

Port Communication Numbers

Virtualization Engine Service Codes

TABLE A-4

lists the service code numbers for errors that occur on the virtualization

engine, along with recommendations for corrective action

:

TABLE A-3

Port CommunicationNumbers

Port

Port

Port Number

Daemon

Management programs

20000

Daemon

Daemon

20001

Daemon

Virtualization engine

25000

Virtualization engine

Virtualization engine

25001

TABLE A-4

Virtualization Engine Service Codes —0 -399 Host-Side Interface Driver Errors

Service Code Number

Cause of Error

Recommended Corrective Action

005

A PCI bus parity error has
occurred.

• Replace the virtualization
engine.

24

The attempt to report one error
resulted in another error.

• Cycle power to the
virtualization engine.

40

The database is corrupt.

• Clear the SAN database.
• Cycle power to the
virtualization engine.
• Import the SAN zone
configuration

41

The database is corrupt.

• Clear the SAN database.
• Cycle power to the
virtualization engine.
• Import the SAN zone
configuration.

42

The zone mapping database is
corrupt.

• Import the SAN zone
configuration

Advertising
This manual is related to the following products: