Sun StorEdge 3900 and 6900 2.0 Series Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

The host, using multipathing software, is presented with two primary (active) paths
for each LUN, allowing the host to route I/O through either or both HBAs.

If a path failure occurs before the second tier of Sun StorEdge network FC switch-8
and switch-16 switches, one of the paths is disabled—but the other path continues
sending I/O as it normally would and takes over the entire load. Refer to

FIGURE 2-4

,

which illustrates a path failure before the second tier of switches.

No Sun StorEdge T3+ array failure is noted because of the redundant path, by way
of the Sun StorEdge network FC switch-8 and switch-16 switch T ports.

FIGURE 2-4

Path Failure—Before the Second Tier of Switches

LUN0 - 10G

Active-MPDrive 0

LUN1-10G

Active-MPDrive1

LUN0 - 10G

Active-MPDrive0

LUN1 - 10G

Active-MPDrive1

Host with HBA-0 and HBA-1

Switch

Switch

Switch

SAN

Database

MPDrive

Carved LUNs

Masking

Virtualization

Engine (2)

LUN0 - 500G
Active-Master

LUN1 - 500G
Passive -
Alternate Master

LUN0 - 500G
Passive-Master

LUN1 - 500G
Active -
Alternate Master

Logical Multipath

Drive MPDrive 0

Logical Multipath

Drive MPDrive 1

T3ES

(Master)(0A - 1P)

(Alternate Master)

(1A - 0P)

Switch

FAILURE

Storage I/O and

Virtualization Engine Communications Traffic

Advertising
This manual is related to the following products: