Codeexample57 failed path marked offline, Sun proprietary/confidential: internal use only – Sun Microsystems 6900 User Manual

Page 83

Advertising
background image

Chapter 5

Troubleshooting the Fibre Channel (FC) Links

63

Sun Proprietary/Confidential: Internal Use Only

To verify that the failover

luxadm

display can be used, the failed path is marked

“offline,” as shown in

CODE EXAMPLE 5-7

.

CODE EXAMPLE 5-7

Failed Path Marked Offline

Note –

This type of error may also cause the device to show up as "unusable" in

cfgadm

, as shown in

CODE EXAMPLE 5-8

.

# /usr/sbin/luxadm display /dev/rdsk/c26t60020F200000644>

DEVICE PROPERTIES for disk: /dev/rdsk/

c26t60020F20000064433C3352A60003E82Fd0s2

Status(Port A): O.K.

Status(Port B): O.K.

Vendor: SUN

Product ID: T300

WWN(Node): 50020f2000006443

WWN(Port A): 50020f2300006355

WWN(Port B): 50020f2300006443

Revision: 0118

Serial Num: Unsupported

Unformatted capacity: 488642.000 MBytes

Write Cache: Enabled

Read Cache: Enabled

Minimum prefetch: 0x0

Maximum prefetch: 0x0

Device Type: Disk device

Path(s):

/dev/rdsk/c26t60020F20000064433C3352A60003E82Fd0s2

/devices/scsi_vhci/ssd@g60020f20000064433c3352a60003e82f:c,raw

Controller /devices/pci@a,2000/pci@2/SUNW,qlc@5/fp@0,0

Device Address 50020f2300006355,1

Class primary

State OFFLINE

Controller /devices/pci@e,2000/pci@2/SUNW,qlc@5/fp@0,0

Device Address 50020f2300006443,1

Class secondary

State ONLINE