107

4. Input/output signal settings

4-2. Setting the DVI input signals (option)

4-2-1. Setting the DVI input signals

Set the DVI input signals when the DVI input board (option) or full HD DVI input board (option) has been
connected.
Signals with the following resolutions can be input.
If signals with any other resolution or frequency are input, the picture will turn black.

DVI Input Board (Digital/Analog)

 XGA

(1024

768), 60 Hz

 WXGA

(1280

768), 60 Hz

 SXGA

(1284

1024), 60 Hz

Full-HD DVI Input Board (Digital)

 XGA

(1024

768), 60 Hz

 WXGA

(1280

768), 60 Hz

 SXGA

(1284

1024), 60 Hz

 WSXGA+

(1680

1050), 60 Hz

 UXGA

(1600

1200), 60 Hz

 WUXGA

(1920

1200), 60 Hz

 1080/59.94P (19201080), 59.94 Hz
 1080/50P

(1920

1080), 50 Hz

Press the [INPUT] button to light its indicator and display the INPUT menu.

 Refer to “2-1-5. LCD menu area”.

Turn [F1] to display the INPUT XX sub menu.

(X: A1, A2, B1 or B2)
The input used to set the DVI signals is selected for X.

Turn [F2] to display the third menu of DVIIn.

<Menu

display>

INPUT XX|DVIIn |Mode |Scale |Auto↓
| 3/4 | Dig| Fit-V| Black

Ana Fit-H

Full

White
Init

Turn [F3] to select the signal system using the Mode item.

 Set this when the DVI input board (AV-HS04M3) has been connected.

Dig: Digital input signals of the DVI connector are effective.

Ana: Analog input signals of the DVI connector are effective.