5. System settings

Example of connections (when the unit and a pan-tilt head are connected)

Pan-tilt heads that can be connected: AW-HE100N, AW-PH400P, AW-PH405N, AW-PH360N

Connections for AW-HE100N, AW-PH405N or AW-PH360N

IN2

SIGNAL

GND

REF

EDITOR

COM

TALLY/GPI

PANEL

LAN

2

3

4

5

6

3

2

1

4

5

6

7

8

9

10

11

12

13

14

15

16

C/C

U/C

1

SDI OUTPUTS

SDI INPUTS

DVI-D OUTPUTS

IN/OUT B2

IN/OUT B1

SLOT B

IN/OUT A2

IN/OUT A1

SLOT A

Pr

Pb

Y

Pr

Pb

Y

ANALOG INPUTS

CONTROLLER connector

Cable length: Max. 656 ft. (200 m)
Twisted pair cable (AWG24)

AV-HS450N

AW-HE100N

Analog component signals
(For the connection specifi cations, refer to the
Operating Instructions of the AW-HE100N.)

Analog Input Board

COM connector

<Connection specifications>

1

FRAME GND

2

RXD –

3

TXD +

4

GND

5
6

GND

7

RXD +

8

TXD –

9

FRAME GND

NC

1
2
3
4
5
6
7
8

RXD –

GND

TXD –

RXD +

TXD +

COM

CONTROLLER

(CONTROL IN IP/RP)

1

2

3

4

5

9

8

7

6

1.......8

Pin No.

Signal

Pin No.

Signal

AV-HS450N

AW-HE100N, AW-PH405N, AW-PH360N

: Twisted pair cable

When the AW-HE100N is to be connected to the unit, select a setting which will enable operations to be
controlled by the controller in the “Controller” item of the AW-HE100N’s pan-tilt head unit setting menu ( Pan
Tilt Head Setting ).
For further details, refer to the Operating Instructions of the AW-HE100N.