6. External interfaces

6-2-4. TALLY/GPI

This connector is provided with eight contact input ports (GPI In) for controlling the unit from an external device,
31 ports (GPI Out) for outputting the tally and status information from the unit to the external device, and one port
(ALARM Out) that is used exclusively as the alarm output.
For details of the settings, refer to “5-7-3. Setting the GPI”.

17

1

50

34

18

33

Com

GPI Out
ALARM Out

Example of GPI Out and ALARM connections
Ensure that the conditions given below are satisfied.

Dielectric strength: Max. DC 24 V
Current:

Max. 50 mA

AV-HS450N

(Max. voltage: 24 V)

Tally LED

(Max. current: 50 mA)

Com

GPI In

+3.3 V

Example of GPI In connections
Provide contact inputs.

AV-HS450N

D-sub 50-pin, female, inch screw

Pin No.

Signal name

1

GPI In Com

IN

34

GPI In Com

18

GPI In 1

2

GPI In 2

35

GPI In 3

19

GPI In 4

3

GPI In 5

36

GPI In 6

20

GPI In 7

4

GPI In 8

37

GPI Out Com

A

21

GPI Out 1

5

GPI Out 2

38

GPI Out 3

22

GPI Out 4

6

GPI Out Com

B

39

GPI Out 5

23

GPI Out 6

7

GPI Out 7

40

GPI Out 8

24

GPI Out Com

C

8

GPI Out 9

41

GPI Out 10

25

GPI Out 11

9

GPI Out 12

42

GPI Out Com

D

26

GPI Out 13

10

GPI Out 14

43

GPI Out 15

27

GPI Out 16

11

GPI Out Com

E

44

GPI Out 17

28

GPI Out 18

12

GPI Out 19

45

GPI Out 20

29

GPI Out Com

F

13

GPI Out 21

46

GPI Out 22

30

GPI Out 23

14

GPI Out 24

47

GPI Out Com

G

31

GPI Out 25

15

GPI Out 26

48

GPI Out 27

32

GPI Out 28

16

GPI Out Com

H

49

GPI Out 29

33

GPI Out 30

17

GPI Out 31

50

ALARM Out