System settings, 8. status displays, 8-1. alarm status displays – Panasonic AV-HS450N User Manual

Page 151: 8-2. alarm message

Advertising
background image

151

5. System settings

5-8. Status displays

5-8-1. Alarm status displays

The alert status (alarms) for this unit’s power supply and cooling fan are displayed on the LCD.

Press the [SYSTEM] button to light it, and display the SYSTEM menu.

 Refer to “2-1-5. LCD menu area”.

Turn [F1] to display the Alarm sub menu.

<Menu

display>

SYS 5|Power |Fan | |
Alarm |NoAlarm|NoAlarm| |

Alarm Alarm

The alert status of the power supplies (mainframe and control panel) is displayed in the Power item.
The alert status of the cooling fan (mainframe) is displayed in the Fan item.

NoAlarm: No irregularity
Alarm: Irregularity

5-8-2. Alarm message

A message is displayed on the LCD when an alarm has occurred.

Alarm message displayed

Type of trouble

Operation

ALARM ! FAN STOP

Cooling fan stopped (mainframe)

The alarm message disappears
when a menu operation is
performed.

ALARM ! MF POWER FAILURE

Power supply voltage drop (mainframe)

ALARM ! MF POWER FAILURE &
FAN STOP

Power supply voltage drop and cooling fan
stopped (mainframe)

ALARM ! PANEL POWER FAILURE

Power supply voltage drop (control panel)

ALARM ! PANEL POWER FAILURE &
FAN STOP

Power supply voltage drop (control panel) and
cooling fan stopped (mainframe)

ALARM ! PANEL & MF POWER
FAILURE

Power supply voltage drop (control panel and
mainframe)

ALARM ! PANEL & MF POWER
FAILURE & FAN STOP

Power supply voltage drop (control panel
and mainframe) and cooling fan stopped
(mainframe)

ALARM ! VER IS DISAGREEMENT
PANEL-Ver[] MF-Ver[xxxxxxx]

Mainframe and control panel versions do not
match

Recovery is not possible without
matching the versions of the
mainframe and control panel.
No operations can be performed
from the control panel until versions
are matched up.

ALARM ! LAN CONNECTION
ERROR

LAN communication malfunction between
mainframe and control panel

The message remains displayed
and no operations can be performed
from the control panel until the
trouble is remedied and normal
operation is restored.

Advertising