Quantum Data 802BT User Manual

Page 146

Advertising
background image

136

Chapter 8

Analyzing Digital Sources and Cables

To set delta error patch testing parameters:

1. Using a terminal emulator, establish a terminal connection with the generator. Refer to

Setting up a terminal connection with the generator

” on page 14.

2. Enter the following commands to configure the generator to output a digital signal

(HDMI or DVI):

SROP

2 4

This removes analog friendly mode and configures the generator to output either a DVI

or HDMI signal depending on the interface hardware the generator is equipped with

(DVI or HDMI).

3. (optional) Enter the following commands to set the status display mode:

SROP 8

4. Connect the HDMI/DVI transmit device to the HDMI/DVI Rx connector on the generator.

5. Connect an HDMI/DVI display to the HDMI/DVI Tx connector on the generator.

6. Enter the following commands to load a suitable format for the display under test.

FMTL

DMT0660 // loads the DMT0660 format for testing

FMTU

// applies the DMT0660 format to the generator

7. Enter the following commands to load a suitable static image.

IMGL

FLAT

// loads the static image for testing

IMGU

// applies the image to the generator

8. Enter the following commands to configure the delta patch parameters.

9.

PDSX

128

// sets patch starting at x-pixel 128

PDSY

256

// sets patch starting at y-pixel 256

PDSH

64

// sets patch height at 64 pixel

PDSW

96

// sets patch width at 90 pixels

10. Enter the following commands to run the delta patch test.

PDAU

// captures patch of image

ANIG

1

// enables analyzer images

IMGL DeltaErr

// loads the DeltaErr image

IMGU

// activates the image in the generator