PSPP

Probe Sync Pulse Polarity

Class

Special Sync Probe Pulse

Description

Sets the polarity of the probe pulse on the special sync output. The PSPG? query returns

the current PSPP value.

Command syntax

PSPP polarity

polarity integer

0 = negative

1 = positive

Query syntax

PSPP?

Query response

0 or 1

Other required

commands

The

FMTU

command instructs the generator to use the new settings. The

ALLU

command

updates the hardware to the new settings and redraws the test image.

Related commands

PSPG

,

PSPW

,

PSHD

,

PSVD

,

PSPM

Example

PSPG 1

// Enables probe pulse on special sync

PSPP 1

// Sets probe pulse polarity to positive

ALLU

// Applies the settings