Appendix A Command Reference

EQUB

EQUalization interval Before vertical sync pulse

Class

Format parameter setting - synchronization

Description

Establishes the width of the equalization interval before the vertical sync pulse in each

field whenever a serrated and equalized sync type is selected via either

ASCT

or

DSCT

commands and selected via the

SSST

command. If the type specified for the selected

sync signal is one of the CCIR types, then the actual equalization interval output by the

generator will be 0.5 lines shorter than the whole number specified. The EQUB? query

returns the current setting of EQUB.

Command syntax

EQUB lines

lines

min = 0

max = number of lines after video and before vertical sync

Query syntax

EQUB?

Query response

lines

Other required

commands

The

FMTU

command instructs the generator to use the new setting. The

ALLU

command

updates hardware to the new setting and redraws the test image.

Example

EQUB 3 // Set pre-equalization to 3 lines in buffer
FMTU

// Update hardware to current buffer contents

Advertising