628

Appendix B

Image Reference

Note: The DVSC command can be used to set the swing value between 150 and 1500

mVp-p.

Method

To adjust the swing in 4 mV increments, press the Step key, then turn the Image knob.

Press the Step key again to reset the digital swing value to the default value, which is 1000

mVp-p for all formats.

Dyna

Description

This image has multiple versions that display different sizes of the same pattern. Version 0

is shown below.