802BT/802R Video Test Generator User Guide

729

9477

Error duplicating formats

The <first> memory location parameter used with the FMTD command is greater than the

<last> memory location parameter.

9480

Format not found / Format data missing

The FMTR command tried to read a format from an empty format storage location.

9490

DDC mod not present

The generator hardware configuration does not support DDC communications.

9491

DDC not available

The generator hardware configuration does not support DDC communications.

9492

DDC2B no ACK from receiver

Low level DDC communications failed with Unit Under Test (UUT). No DDC

acknowledgment bit was received from the UUT.

9493

DDC2B arbitration lost

Low level DDC communications failed with Unit Under Test (UUT). DDC bus arbitration

lost with the UUT.

9494

DDC2B timeout on bus

Low level DDC communications failed with Unit Under Test (UUT). DDC communications

timed out with the UUT.

9496

EDID header not found

A valid block of header data could not be found in the EDID data read back from Unit

Under Test (UUT).

9497

DDC old monitor

A DDC compliant Unit Under Test (UUT) could not be found connected to the generator.

9498

I2C address missing

There was a communications error within the generator hardware architecture because

the device address was missing.

9499

I2C count missing

There was a communications error within the generator hardware architecture because

the data count was missing.