Pshd, Pshd probe sync pulse horizontal delay – Quantum Data 802BT User Manual

Page 496

Advertising
background image

486

Appendix A Command Reference

PSHD

Probe Sync Pulse Horizontal Delay

Class

Special Sync Probe Pulse

Description

Sets the delay (in pixels) of the line(s) on which the probe pulse occurs on the special sync

output. The PSHD? query returns the current PSHD value.

Command syntax

PSHD width

width integer

0=PSVD(HTOT - PSPW-1)

Query syntax

PSHD?

Query response

width

Other required

commands

The

FMTU

command instructs the generator to use the new settings. The

ALLU

command

updates the hardware to the new settings and redraws the test image.

Related commands

PSPG

,

PSPW

,

PSPP

,

PSVD

,

PSPM

Example

PSPG 1

// Enables probe pulse on special sync

PSPP 1

// Sets probe pulse polarity to positive

PSPW 10

// Sets probe pulse width to 10 pixels

PSHD 200

// Sets probe pulse horizontal delay to 200 pixels

PSVD 300

// Sets probe pulse vertical delay to 300 pixels

ALLU

// Applies the settings

Advertising