The following table describe the default DCS priority scheme for horizontal sync.

The following table describe the default DCS priority scheme for vertical sync.

To enable the legacy DCS priority scheme:

1. Turn off the generator.

2. Hold down the

Step

and

DCS

keys while starting the generator.

The generator will remain in this mode through subsequent power cycles until the

generator is re-initialized or reset with the “No special modes” command (hold down

ACS+DCS+DSS while starting the generator).

OUTG

SSST

HSPG

HS Output

HS Polarity

0

Do not care

Do not care

No signal

Do not care

1

Do not care

0

No signal

Do not care

Do not care

8 (DPMS – OFF)

Do not care

No signal

Do not care

1

9 (DPMS – SUS-
PEND)

Do not care

Horizontal Sync

HSPP

1

10 (DPMS –
STANDBY)

Do not care

No signal

Do not care

1

1, 3, 5, 7, or 11

1

Horizontal Sync

HSPP

1

2, 6, or 11 (DCS)

1

Composite Sync

CSPP

OUTG

SSST

VSPG

VS Output

VS Polarity

0

Do not care

Do not care

No signal

Do not care

1

Do not care

0

No signal

Do not care

Do not care

8 (DPMS – OFF)

Do not care

No signal

Do not care

1

9 (DPMS – SUS-
PEND)

Do not care

No signal

Do not care

1

10 (DPMS –
STANDBY)

Do not care

vertical Sync

VSPP

1

1, 3, 5, 7, or 11

1

vertical Sync

VSPP

1

2, 6, or 11 (DCS)

1

Composite Sync

CSPP

Advertising