802BT/802R Video Test Generator User Guide

717

2390

Vertical pulse too large for interlaced format

The vertical sync pulse width combined with the number of pre and post-equalization

pulses for an interlaced format is greater than the maximum supported by the generator

hardware configuration.

2391

Incompatible analog composite sync & digital composite sync types

The generator hardware configuration does not support the video format outputting both

analog composite sync and digital composite sync type selections at the same time.

2392

Incompatible analog composite sync & digital separate sync types

The generator hardware configuration does not support the video format outputting both

analog composite sync and digital separate sync type selections at the same time.

2393

Analog composite sync type not compatible with analog video type

The generator hardware configuration does not support the video format’s analog

composite sync type being added to the current analog video type.

2394

ACS available on green only

The generator hardware configuration supports adding analog composite sync to only the

green analog video output

2395

Sync type selection incompatible with analog video type selection

The video format’s analog video type selection requires the use of analog composite sync.

2396

Invalid analog composite sync type

The current firmware does not support the format’s analog composite sync type parameter

value (ASCT setting) or the generator hardware configuration does not support a video

format’s analog composite sync type for non-interlaced operation.

2397

Invalid digital composite sync type

The current firmware does not support the format’s digital composite sync type parameter

value (DSCT setting) or the generator hardware configuration does not support a video

format’s digital composite sync type for non-interlaced operation.

2398

Invalid digital separate sync type

The current firmware or generator hardware configuration does not support the format’s

digital separate sync type parameter value (DSST setting)

2399

Invalid sync type selection

The current firmware does not support the format’s active sync type selection (SSST

setting).