Pnsp, Pnsp pseudo noise signal procedure – Quantum Data 802BT User Manual

Page 491

Advertising
background image

Video Test Generator User Guide

481

PNSP

Pseudo Noise Signal Procedure

Class

Signal Analyzer - Pseudo-random noise

Description

Selects the procedure used when making pseudo-random noise measurements.

PNSP procedure

procedure

0 = CONTINUOUS (stop after key press, knob turn, or any I/O). In this mode, noise

testing continues until either a key-press, a knob-turn, or serial/GPIB/host I/O port

activity is detected. To stop the CONTINUOUS mode remotely via the I/O ports, a “\r”

is recommended.

1 = SINGLE SHOT (stop after one run-length). In this mode, a single run-length is

executed before the pseudo-random noise measurement is stopped.

n = MULTI SHOT (stop after n run-length shots). In this mode, a number of run-lengths

(n) are executed before pseudo-random noise measurement is stopped and results

become available.

Query syntax

PNSP?

Query response

0 - 2

Example

PNSP 23 // run 23 sequences of the pseudo-random noise measurement
PNGU

Related commands

PNGU

Advertising
This manual is related to the following products: