Hrat, Hrat horizontal rate – Quantum Data 802BT User Manual

Page 377

Advertising
background image

Video Test Generator User Guide

367

HRAT

Horizontal RATe

Class

Format parameter setting - Video resolution

Description

Sets the line frequency. Pixel rate is equal to HTOT multiplied by HRAT. Frame rate is

equal to HRAT divided by VTOT. Field rate is equal to SCAN multiplied by the frame rate.

The HRAT? query returns the current horizontal frequency setting.

Command syntax

HRAT frequency

frequency

typical min = 1000 Hz (floating point accepted)

typical max = 130000 Hz (floating point accepted)

Query syntax

HRAT?

Query response

frequency in Hz (floating point returned)

Other required

commands

The

FMTU

command instructs the generator to use the new settings. The

ALLU

command

updates the hardware to the new settings and redraws the test image.

Example

HRAT 32768 // Set 32.768 kHz rate in buffer
FMTU

// Update hardware to current buffer contents

or

HRAT 32.768E3 // Set a 32.768 kHz rate
FMTU

// Update hardware to current buffer contents