2130

Horizontal active too small

The number of active pixels per horizontal scan line is less than the minimum supported

by the generator hardware configuration.

2140

Horizontal blanking too small

The video format’s horizontal blanking period expressed in microseconds and/or number

of pixel clock cycles is not supported by the generator hardware configuration.

2141

Horizontal blanking too small

Same as Error number 2140. Found in some firmware releases for different generator

hardware configurations.

2150

Horizontal blanking too small

Same as Error number 2140. Found in some firmware releases for different generator

hardware configurations.

2151

Horizontal total less than horizontal resolution

The video format’s total (active + blanked) number of pixel clock cycles per horizontal scan

line can not be less than the number of active pixels per scan line.

2152

Horizontal resolution too large or Horizontal blanking too small

Same as Error number 2140. Found in some firmware releases for different generator

hardware configurations.

2155

Horizontal blanking too small

Same as Error number 2140. Found in some firmware releases for different generator

hardware configurations.

2180

Horizontal pulse width too small

The generator hardware configuration does not support video formats having horizontal

sync pulse widths less than one pixel clock cycle long.

2181

Horizontal sync pulse width not even

Number of pixel clock cycles in the horizontal sync pulse width must be evenly divisible by

2 at the current pixel clock rate for the video format and generator hardware configuration.

2190

HSPW too small for HDTV sync

The generator hardware configuration does not support video formats having horizontal

sync pulse widths less than two pixel clock cycles long for the current video and HDTV

sync type selections.