182

Chapter 10

Testing EDID

2. Press and hold the R key and then press and release the ACS key. Alternatively power

off the generator, press and hold both the R and ACS keys then power up the generator

to configure the generator knob list with the hot plug formats.

The initial compliance test screen re-appears and the Format knob list includes only

those formats in the display EDID.

Visual verification of formats

Additional visual inspection of Tests 8-19 and 8-20 is necessary to ensure that each

format can be loaded and displayed at each pixel encoding and at its minimum and

maximum pixel rate.

Test ID 8-19 involves testing each format with different YCbCr pixel encoding: 4:4:4 pixel

sampling and 4:2:2 sampling. Test ID 8-20 requires that each format listed in the EDID be

be tested at two different pixel clock frequencies. The two different frequencies shall be the

minimum and maximum permitted by a Source. For 50Hz formats, these values are

49.75Hz and 50.25Hz (50Hz ± 0.5%). For 59.94Hz or 60Hz formats, these frequencies are

59.64Hz (59.94Hz – 0.5%) and 60.3Hz (60Hz + 0.5%). The tested pixel clock frequency

accuracy shall be ±0.05%.

A separate listing of the formats is provided on the Format knob list to support this visual

inspection testing. The nomenclature for visual inspection testing of maximum and

minimum pixel rate is of the form shown in the example below: