Psvd, Psvd probe sync pulse vertical delay – Quantum Data 802BT User Manual

Page 501

Advertising
background image

Video Test Generator User Guide

491

PSVD

Probe Sync Pulse Vertical Delay

Class

Special Sync Probe Pulse

Description

Sets the line in the frame or field that the probe pulse occurs on the special sync output.

The PSVD? query returns the current PSVD value.

Command syntax

PSVD line

line integer

0 = PSVD(VTOT-1)

Query syntax

PSVD?

Query response

line

Other required

commands

The

FMTU

command instructs the generator to use the new settings. The

ALLU

command

updates the hardware to the new settings and redraws the test image.

Related commands

PSPG

,

PSPW

,

PSPP

,

PSHD

,

PSPM

Example

PSPG 1

// Enables probe pulse on special sync

PSPP 1

// Sets probe pulse polarity to positive

PSPW 10

// Sets probe pulse width to 10 pixels

PSVD 300

// Sets probe pulse vertical delay to 300 pixels

ALLU

// Applies the settings