374

Appendix A Command Reference

HSRS

Horizontal Sync Rate Shift

Class

System parameter settings

801GC, 801GC-ISA, 801GF, 801GF-ISA and 801GX only

Description

Temporarily shifts the horizontal sync frequency of the generator. The first parameter

controls the amount of shift (in Hz) and the second parameter controls the approximate

length of time (in seconds) that the frequency is shifted, before returning to nominal. Both

parameters can be entered as floating point numbers.

Command syntax

HSRS shift_factor shift_period

shift_factor

should not exceed ±10% of normal horizontal rate to ensure stable operation of the

generator

shift_period

non-negative

Example

HSRS -100 2.5 // Shifts the horizontal rate of the currently running

// format down by 100 Hz for about 2.5 sec.