Mode, Mode communications mode – Quantum Data 802BT User Manual

Page 449

Advertising
background image

Video Test Generator User Guide

439

MODE

communications MODE

Class

System parameter settings

Description

Sets the serial port communications parameters of a stand-alone model generator. The

changes take effect as soon as the command is entered. The factory default settings are

2400 baud, no parity, 8 data bits, no stop bits, no handshake, and no protocol.

Command syntax

MODE baud parity data stop handshake protocol

baud rate

300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200 bits/sec

parity

N = None, E = Even or O = Odd

data

number of data bits: 7 or 8

stop

number of stop bits: 1 or 2

handshake

N = None

H = Hardware (CTS/RTS)

protocol

N = None

Y=Y-Modem

Example

MODE 9600 N 8 1 H N // Set a stand alone generator to

// communicate at 9600 Baud, No parity, 8 data bits,
// 1 stop bit, RTS//CTS handshaking and No protocol

or

MODE 2400 // Change only the baud rate

Advertising