Wolf DCX-1000I User Manual
Page 117
Wolf Cinema Owner's Manual
B-17
P6 = input polarity & routing
Bits 2-0 // horizontal sync source
0 = no sync
1 = horizontal on vertical input
2 = horizontal on horizontal input
3 = horizontal on green input
4 = horizontal on red input
5 = horizontal from Vid1 input
6 = horizontal from Vid2 input
Bit 3 // set if composite sync (H & V on same wire)
Bit 4 // set if horizontal sync has negative polarity
Bit 5 // set if vertical sync has negative polarity
Setting 1
= reply message for first source setup setting
Setting 2
= reply message for second source setup setting
Setting 3
= reply message for third source setup setting
etc…
Setting n
= reply message for last source setup setting
$
acknowledge of DTa message (if requested)
example:
($DTa? S5)
(DTa! S005 000 001 05996 03150 059)
(COn! S005 045)
(BrT! S005 167)
etc…
$
ReaDInG seTTInGs (DaTa) FOR all sOURCe seTUP
To request all settings for all sources, use P1=0 ($DTa? S0). The reply will be a sequence of
replies for each source. if you requested an acknowledgement ($), it will arrive after the last reply
for the last source.
example:
($DTa? S0)
(DTa! S005 000 001 05996 03150 059)setup
(COn! S005 045)
(BrT! S005 167)
etc.…
(DTa! S034 000 001 05996 03150 059)
(COn! S034 022)
(BrT! S034 137)
etc.…
$
DOWnlOaDInG sOURCe seTUP seTTInGs (DaTa) TO a PROJeCTOR
Send a DTA message to define a new source setup, or redefine an existing source setup, and
include the specified parameters (refer back to the “Reading Setting for a Specific Source Setup”
list of parameters shown above).
example:
(DTa S005 000 001 05996 03150 085)
(COn S005 045)
(BrT S005 167)
etc.…
(DTa S034 000 001 05996 03150 085)
(COn S034 022)
(BrT S034 137)
etc.…