Wolf DCX-1000I User Manual

Page 131

Advertising
background image

Wolf Cinema Owner's Manual

B-31

lDT level Detector
enable (1) or disable (0) the lDT (level Detector Test) mode that can aid in setting up input

levels. Use in conjunction with LDV (Level Detector Value), which defines a threshold below
which all incoming colors will be turned black, and above which all colors will turn to white. at this
point, the level Detector will be enabled.

lDV level Detector Value
Use an lDV setting of 1 to 1023 when the lDT (see above) will be enabled. This is a threshold
below which all incoming colors will be turned black, and above which all colors will turn to white,
and is an aid for setting up input levels.


lHO lens Horizontal Offset
lHO adjusts horizontal offset on projectors having a motorized lens mount, and requires keypad
emulation.

examples:

(LHO K3)

Move the image to the right •

(LHO K2)

Move the image to the left •

(lHO K0)

Stop horizontal movement (without this, lens movement will

continue until it reaches the end stop).

To “nudge” the image a minimum distance, script in a delay between (lHO K3) and (lHO K0).

Depending on your application, a delay of at least 20-30 milliseconds may be sufficient.

lTC lamp Tracking Calibration
Use lTC to calibrate the current lamp and optical response.

Parameter

Description

P1 = Calibration

0 = Use default settings
1 = run automatic calibration on current projector
or, if more parameters present,
1= Set custom gain and offset

P2 = Gain

Gain value can be from 0 to 32767

P3 = Offset

Offset value can be between -32768 to 32767

notes: lTC calibration can take several minutes to complete and will vary the lamp output during
calibration. all lamp settings will return to their initial condition once the calibration has been
completed.

Warning: Custom settings allow the user to set LTC to any value within the specified range. The

software does not check that the specified values are functional.

lMe lamp Message enable
Use lme to enable (1) or disable (0) display of the lamp timer message when the lamp has
reached its Lamp Limit setting.

lnG language
Use lnG to get/set the current language used in the projector’s menu system.
1 = english

4 = German

2 = French

5 = italian

3 = Spanish

3.79 lDT

level Detector

3.80 lDV

level Detector Value

3.81 lHO

lens Horizontal Offset

3.82 lTC

lamp Tracking

Calibration

3.83 lMe

lamp Message enable

3.84 lnG

language