Wolf DCX-1000I User Manual
Page 122
Wolf Cinema Owner's Manual
B-22
FRD Frame Delay
Use FrD to adjust the number of lines of delay between the input and output frames (range
varies with incoming signal).
FRZ Freeze Image
FrZ 1 = freeze the image. FrZ 0 = unfreeze the image.
Fse Fan sensor enable
Use FSe if you want the projector to shut down 3 minutes after a critical cooling fan failure. FSe
1 = enabled, FSE 0 = disabled. NOTE: Definition of a which cooling fan is critical varies with
projector model.
FYI For Your Information
The projector broadcasts an Fyi message when it detects a change in status. The Fyi message
contains the relevant status code followed by its new state (P1), up to 2 additional parameters of
detail, and a brief text description. The address of the source projector precedes the Fyi code.
NOTE: FYI messages are gated by the Error Message Enable (EME) control. Turning off EME
also turns off FYI.
status Code
new state (P1)
Meaning and additional Parameters
001 Power
0 = Off 1 = On 2 = Boot 10
= Cool Down 11 = Warm Up
P1 value indicates the new “Power” state
detected.
002 Proj. address
##### (5-digit address)
P1 value indicates the new address of
this source projector.
003 Proj. Selected
0 = rS232 inactive, Ui
inactive 1 = rS232 inactive,
Ui active 2 = rS232 active,
Ui inactive 3 = rS232
active, Ui active
This projector has been activated or
inactivated via the PrOJ key or the aPJ
serial message.
004 Baud rate
####### (7-digit baud rate)
P1 value indicates the new baud rate.
005 Standby
0 = Off 1 = On
P1 value indicates whether the system is
in standby mode
006 Signal
0 = Good Signal 1 = Signal
missing 2 = bad sync
P1 describes signal detection P2 = hor.
frequency of signal P3 = vert. frequency
of signal
007 OSD
0 = Off 1 = On
P1 value indicates whether the on-
screen display is on or not.
009 Shutter
0 = Open 1 = Closed
P1 value indicates whether the shutter is
open or closed.
010 input
0 = Open 1 = Closed
P1 describes the current channel
number P2 = Switcher# (projector is
always switcher “000”) P3 = Slot#
011 Picture mute.
0 = Off 1 = On
P1 value indicates whether the picture is
displayed or not
012 PiP.
0 = Off 1 = On
P1 value indicates whether Picture-in-
Picture mode is on or not
255 General / misc. ### (3-digit channel
number)
P1 describes miscellaneous general
state detected
3.53 FRD
Frame Delay
3.54 FRZ
Freeze Image
3.55 Fse
Fan sensor enable
3.56 FYI
For Your Information
Appendix B ► Serial Communications