B-38

3.122 PWR

Power

PWR Power
Use PWr to turn the projector power on or off, or to use special modes during a download, or to
see the current power state.

0 = Off

1 = On

2 = Boot mode (for downloading new code only) DO nOT Use

3 = no lamp (powered up, but lamp is off. For downloading only.)

11 = Warming up (read only)

PXP Pixel Phase
Use PXP to adjust the position of the sampling clock relative to the video data. available range
depends on the incoming signal, with a higher frequency source having ½ the range of a lower
frequency source.

PXT Pixel Tracking
Use PXT to adjust the number of pixels/lines in the image. range depends on the horizontal
sync frequency.

Rbl Right blanking
Use rBl to blank the right edge of the image (0-1000). The amount of blanking feasible depends
on the incoming source data.

RDb Red blacklevel

Set or request the red Blacklevel (0-511) for a specific source setup.

RDD Red Drive

Set or request the red Drive (0-511) for a specific source setup.

ReM Remote Commands

Allows arbitrary serial data to be sent out a specified port and the data can also be read from that
port. it is intended to be used in conjunction with the rTe commands to allow a single event to
control other equipment connected to the projector.

Before being used, a port must be configured. After configuration, the port cannot be used for

standard Wolf Cinema protocol commands until that port is reconfigured as a Wolf Cinema port

again. See tables below for setting port configuration, reading port configuration and sending
and receiving arbitrary data from a port.

Configuring a Port

P1 = Port

P2 = Port Configuration P3 = Baud Rate

1 = rS232 in
2 = rS232 OUT

3 = rS422 (db9)
4 = rS422 (Xlr – only some models)
5 = rS422 (Xlr – only some models)

r = remote equipment
C = Wolf Cinema
standard protocol

Same as for the BDr
command (i.e. 96, 1152
or 115200…)


examples:

(REM 2 r 96): Configures the OUT port to send arbitrary data at 9600 baud

(rem 2 c): returns the OUT port to normal operation

3.123 PXP

Pixel Phase

3.124 PXT

Pixel Tracking

3.125 Rbl

Right blanking

3.126 RDb

Red blacklevel

3.127 RDD

Red Drive

3.128 ReM

Remote Commands