Wolf DCX-1000I User Manual

Page 141

Advertising
background image

Wolf Cinema Owner's Manual

B-41

P3 = State/details (opt.)

P3 only applies if:
P2 = 1 (Power)
if P3 is 0 = Power Off
if P3 is 1 = Power On
P2 = 2 (error)
P3 = error number
P2 = 5 (Signal input)
P3 = input number
P2 = 6 (Signal Channel)
P3 = Channel number

This optional parameter further

defines the state. If this is
omitted, assume the event will

fire on any system event of this
type (for example, all signal
input changes rather than a

specific one)

If P1 = F or f

Description

Meaning

P1 = F or f

FUnC key event

This is a real-time event that
triggers a command when the

specified FUNC # is pressed.

P2 = number key

1-5, 7-9

The number to trigger from.

If P1 = X or x

Description

Meaning

P1 = X or x

System event

This deletes a stored event.

P2 = Target

* = Delete all events
d = Delete all pending events
waiting because of a Dly
command.
number = Delete the event
with the given number from
the list

This parameter determines
which events will be deleted.

examples:

(rTe g 7 H “(GiO 22 P 100)”)

(rTe g 7 H “(GiO 22 P 100) (GiO 1 l)”)

(rTe G 7 H “(GiO 22 P 100) (GiO 1 l)”)

(rTe T 2003/07/09 12:36:45 S "(PWr 1)") = "S" Single / one time

(rTe T 2003/07/09 18:00:00 D "(PWr 0)") = "D" Daily

(rTe T 2003/07/09 05:00:00 W "(PWr 0)") = "W" Weekly

(rTe F 3 “(FrZ 1)”)

// freeze image when FUnC-3 pressed

(rTe D 00:05:00 "(PWr 0)")

= in 5 minutes, turn the projector off

(rTe G 5 H “(Dly 100) (PWr 0)”) = When pin 5 goes high, delay 100ms, then

power off.

(rTe?)

(rTe!000 T 2003/07/09 05:00:00 S "(PWr 0)")

(rTe!001 T 2003/07/09 12:36:45 S "(PWr 1)")

(rTe!002 T 2003/07/09 18:00:00 D "(PWr 0)")


(rTe?0)

(rTe!000 T 2003/07/09 05:00:00 S "(PWr 0)")


(rTe X 1): delete entry one

(rTe X *): delete all entries

(rTe X d): delete all pending events waiting because of a (Dly) command

Appendix B ► Serial Communications