Real Time Event

Use the serial command rTe to specify an action that is initiated at a particular time or based
on an external stimulus.

For General Purpose IO “G”

Parameter

name

Value

P1

rTe type

G (real Time i/O event)

P2

i/O bit

1-7

P3

Pin state
(1 Character)
(String)

H = High
l = low
“lHXXXHl” Combine multiple inputs and trigger occurs
when all conditions are met

P4

Commands

any valid serial protocol command for the device

example 2. Projector powers up when a switch on the external device is turned on.

(GIO C2 I)

Set pin #2 configuration as input

(RTE G 2 H “(PWR 1)”)

Power on when pin #2 set to high

(RTE G 2 L “(PWR 0)”)

Power off when pin #2 set to low