Wolf Cinema Owner's Manual

3-36

Section 3 ► Operation

Rs232 anD Rs422 JOIneD: messages originating from an rS232 or rS422 controller will be
relayed to all rS232or rS422 ports. any ethernet communication, however, will not.

Rs232 anD eTHeRneT JOIneD: messages to and from the rS232 ports will also be relayed
to the ethernet port, and vice versa. any rS422 communications will be isolated.

all JOIneD: all messages reach all ports, regardless of type.

Ethernet Settings

- SUBMENU

nOTe: Recommended for network administrators only.

DHCP: enable this checkbox if you want a DHCP server to automatically change the projector’s
default iP address (0.0.0.0) to one that is valid and unique for use on the current ethernet
network. On networks without a DHCP server, or to simply override the automatic DHCP server
function, delete the checkmark and enter the new “iP address” settings desired. remember
that only a 0.0.0.0 address will trigger the DHCP addressing service, and only when the DHCP
checkbox is enabled.

IP aDDRess: enter a valid and unique iP address for use on the network to which the projector is
currently connected. This address will overwrite any previous iP address such as the projector’s

factory-defined default (0.0.0.0), or one that has been assigned by a DHCP server or other user.
it takes approximately 10 seconds for the projector to respond at its new address.

PORT:

On some Ethernet networks, firewall restrictions may require that the port number of the

projector be changed from its default of 3002. if so, enter a new valid port number here. it is
highly recommended not to use a port # below 1000, as these ports are typically reserved for and
used by common iP applications.

sUbneT MasK anD DeFaUlT GaTeWaY: The Subnet mask and Default Gateway are
automatically assigned when DHCP is enabled. if a static iP is being used, the iP must be

assigned first since the projector estimates the subnet mask after the IP is entered. The Default
Gateway is an optional router device used to send and receive data outside the subnet.

neTWORK naMe: Set the name for the projector, as it should appear on the local network.
The control is most useful when DHCP is enabled, since the iP address may change from one
session to another.