3.116 PnG

Ping

PnG Ping
Use PnG to request and get basic projector information such as the type of projector & main
software version installed on the TiPm (10-bit image Processor module).

P1 = Wolf Cinema projector type

□ 31 = a projector listed on page 3 (always). These all include a TIPM.

□ 0 = the projector is not initialized

P2 = major s/w version# (0-99)

P3 = minor s/w version# (0-99)

P4 = maintenance version# with no functional change (a-z)

P5 = Beta version#, if applicable only (1-199)

P6 = Variation, such as an Oem. Preceded with “T” (T1-T63)


examples:
(png?) (png! 031 001 000)

// TiPm version 1.0

(png?) (png! 031 002 005 b)

// TiPm version 2.5b

(png?) (png! 031 003 001 T005)

// TiPm version 3.1 T5 (=variation of released version v3.1)

(png?) (png! 031 001 000 c 045 T002) // TiPm version 1.0c.045 T2 (=variation of beta version
1.0c.045)

PPP PIP Position Preset
Use PPP to select the preferred position and size for the Picture-in-Picture window.

0 = Top right

1 = Top left

2 = Bottom left

3 = Bottom right

4 = Custom (response only – The size and position do not correspond to any of the

defaults.)

PPs PIP swap
Use PPS to swap the picture-in-picture window with the main window. PPS is a toggle command
with no parameters.

PsW alternative service Password

Use PSW to find out the most recently defined password for accessing the service menu, or

to define an alternative service password (range = 0-32768). Note that defining an alternative
PSW simply adds a password to projector memory so that you may use either the original

factory-defined Wolf Cinema password (which is always valid) or this new password. Because

(PSW?) will find only the most recently defined password, the factory-defined password cannot
be retrieved in this manner once you have created an alternative password. Use PWe to enable/
disable passwords as described below.

PVP PIP Vertical Position
Use PVP to set the vertical position (0-100) of the picture-in-picture window. Values represent
what percentage of the screen size is used for the picture-in-picture window.

PWe Password enable
enable (1) or disable (0) the service password for access to the service menu.

3.117 PPP

PIP Position Preset

3.118 PPs

PIP swap

3.119 PsW

alternative service

Password

3.120 PVP

PIP Vertical Position

3.121 PWe

Password enable