Wolf DCX-1000I User Manual

Page 75

Advertising
background image

Wolf Cinema Owner's Manual

3-51

nOTe: Enter a serial number only if you have just installed a new lamp. This will help ensure
that lamp timer is not reset on an old lamp and that the number of hours logged on the lamp will
be accurate.

IMPORTanT: always record the serial number of a neW lamp.

When a new lamp is installed and its serial
number recorded by selecting “Change lamp”
in the Lamp menu, the lamp timer resets to
“0” and begins logging time for the new lamp.
This tally appears in both the Lamp menu (see
right) and the Information menu.

To review the number of hours logged for
previous lamps, consult the Lamp History
menu.

if the “lamp message” checkbox has been
enabled in the Lamp menu (recommended),
an expiry message will appear upon power-up

when the lamp has reached its defined “Lamp
limit”. The lamp should be replaced.

The “lamp limit” setting should not exceed the expected lamp life, as an old lamp becomes
increasingly fragile and more prone to sudden failure.

The read-only Information menu lists a variety of details about the standard and optional
components currently detected in the projector. refer to the Information menu for versions of
hardware and software installed, the type (size) of lamp, the hours logged in total and for a

specific period (such as a rental period), and for your projector model name and serial number.
in addition, the Information

menu identifies the current channel, its location, its frequencies and

other details.

Scroll the full Information menu using   . Use   for page up/down.

Section 3 ► Operation

How Old is My Lamp >

When to Replace the Lamp >

Iris

Information Menu >

Advertising
This manual is related to the following products: