2.1 Installation Site Check List

The drive relies on the ambient air for cooling.
Observe the limitations on ambient air
temperature for optimal operation

Ensure that the installation location has sufficient
support strength to mount the drive

Keep the drive interior free from dust and dirt.
Ensure that the components stay as clean as
possible. In construction areas, provide a
protective covering. Optional IP55 (NEMA 12)
enclosures may be necessary.

Keep the manual, drawings, and diagrams
accessible for detailed installation and operation
instructions. It is important that the manual is
available for equipment operators.

Locate equipment as near to the motor as
possible. Keep motor cables as short as possible.
Check the motor characteristics for actual
tolerances. Do not exceed

300m (1000ft) for unshielded motor
leads

150m (500ft) for shielded cable.

2.2 Drive and Motor Pre-installation Check

List

Compare the model number of unit on the
nameplate to what was ordered to verify the
proper equipment

Ensure each of the following are rated for same
voltage:

Mains (power)

Drive

Motor

Ensure that drive output current rating is equal to
or greater than motor full load current for peak
motor performance

Motor size and drive power must match
for proper overload protection

If drive rating is less than motor, full
motor output cannot be achieved

2.3 Mechanical

Installation

2.3.1 Cooling

To provide cooling airflow, mount the unit to a
solid flat surface or to the optional back plate
(see 2.3.3 Mounting)

Top and bottom clearance for air cooling must be
provided. Generally, 100-225mm (4-10in) is
required. See Illustration 2.1 for clearance
requirements

Improper mounting can result in over heating
and reduced performance

Derating for temperatures starting between 40

°C

(104

°F) and 50°C (122°F) and elevation 1000m

(3300ft) above sea level must be considered. See
the equipment Design Guide for detailed
information.

Illustration 2.1 Top and Bottom Cooling Clearance

Size

12

13

-

15

21

22

a/b (mm)

100

100

-

100

200

200

a/b (in)

4

4

-

4

8

8

Size

23

24

31

32

33

34

a/b (mm)

200

200

200

225

200

225

a/b (in)

8

8

8

9

8

9

Table 2.1 Minimum Airflow Clearance Requirements