4.1.2 Setting Keypad Display Values
The display area is activated when the frequency converter
receives power from mains voltage, a DC bus terminal, or
an external 24V supply.
The information displayed on the keypad can be
customized for user application.
•
Each display readout has a parameter associated
with it.
•
Options are selected in the menu Keypad Set-up.
•
Display 2 has an alternate larger display option.
•
The frequency converter status at the bottom line
of the display is generated automatically and is
not selectable. See 7 Status Messages for
definitions and details.
Display
Parameter number
Default setting
1.1
K-20
Motor RPMs
1.2
K-21
Motor current
1.3
K-22
Motor power (kW)
2
K-23
Motor frequency
3
K-24
Reference in percent
4.1.3 Display Menu Keys
Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
Key
Function
Status
Press to show operational information.
•
In Auto mode, press and hold to toggle
between status read-out displays
•
Press repeatedly to scroll through each
status display
•
Press and hold [Status] plus [
▲
] or [
▼
] to
adjust the display brightness
•
The symbol in the upper right corner of the
display shows the direction of motor
rotation and which set-up is active. This is
not programmable.
Quick Menu
Allows access to programming parameters for
initial set up instructions and many detailed
application instructions.
•
Press to access Quick Start for sequenced
instructions to program the basic frequency
controller set up
•
Press to access Fan Macros, Pump Macros,
Compressor Macros, or Closed Loop for
sequenced instructions to program
applications
•
Press to access Trending for realtime
logging on keypad display.
•
Press to access Parameter Data Check for
changes in parameter data set.
•
Follow the sequence of parameters as
presented for the function set up
Main Menu
Allows access to all programming parameters.
•
Press twice to access top-level index
•
Press once to return to the last location
accessed
•
Press and hold to enter a parameter
number for direct access to that parameter
Alarm Log
Displays a list of current warnings, the last 10
alarms, and the maintenance log.
•
For details about the drive before it entered
the alarm mode, select the alarm number
using the navigation keys and press [OK].
User Interface
AF-600 FP Operating Instructions
25