Caution – GE Industrial Solutions AF-600 FP Fan & Pump Drive (230V to 60HP, 460_575V to 125HP) User Manual
Page 72
Surroundings:
Unit Size 1x types
IP 20/Chassis, IP 21kit/Type 1, IP55/Type12
Unit Size 21 and 22 types
IP55/Type12
Unit Size 23 and 24 types
IP20/Chassis
Unit Size 31 and 32 types
IP55/Type 12
Unit Size 33 and 34 types
IP20/Chassis
Unit Size 41, 42, and 51 types
IP21/Type 1, IP54/Type12
Unit Size 43, 44, and 52 types
IP00/Chassis
Unit Size 61/63
IP21, 54/Type1, 12
Unit Size 62/64
IP21, 54/Type1, 12
IP21/Nema 1 kit for all unit sizes 1x, 2x, and 3x
IP21/NEMA 1/on top of enclosure
Vibration test all enclosure types
1.0g
Relative humidity
5% - 95% (IEC 721-3-3; Class 3K3 (non-condensing) during operation
Aggressive environment (IEC 60068-2-43) H
2
S test
class Kd
Test method according to IEC 60068-2-43 H2S (10 days)
Ambient temperature (at 60 AVM switching mode)
- with derating
max. 50
°C
1)
- with full output power of typical EFF2 motors (up to 90% output current)
max. 50
°C
1)
- at full continuous Drive output current
max. 45
°C
1)
1)
For more information on derating see the AF-600 FP Design Guide, section on Special Conditions.
Minimum ambient temperature during full-scale operation
0
°C
Minimum ambient temperature at reduced performance
- 10
°C
Temperature during storage/transport
-25 - +65/70
°°C
Maximum altitude above sea level without derating
1000m
Maximum altitude above sea level with derating
3000m
Derating for high altitude, see section on special conditions
EMC standards, Emission
EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3
EMC standards, Immunity
EN 61800-3, EN 61000-6-1/2,
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6
See section on special conditions!
Control card performance:
Scan interval
5 ms
Control card, USB Serial Communication:
USB standard
1.1 (Full speed)
USB plug
USB type B “device” plug
CAUTION
Connection to PC is carried out via a standard host/device USB cable.
The USB connection is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
The USB connection is not galvanically isolated from protection earth. Use only isolated laptop/PC as connection to the USB
connector on drive or an isolated USB cable/converter.
Specifications
AF-600 FP Operating Instructions
69
10
10