4.1.4 Navigation Keys

Navigation keys are used for programming functions and
moving the display cursor. The navigation keys also
provide speed control in local (hand) operation. Three
drive status indicator lights are also located in this area.

Key

Function

Back

Reverts to the previous step or list in the menu

structure.

Cancel

Cancels the last change or command as long as

the display mode has not changed.

Info

Press for a definition of the function being

displayed.

Navigation

Keys

Use the four navigation arrows to move between

items in the menu.

OK

Use to access parameter groups or to enable a

choice.

Light

Indicator

Function

Green

ON

The ON light activates when the

drive receives power from mains

voltage, a DC bus terminal, or an

external 24 V supply.

Yellow

WARN

When warning conditions are met,

the yellow WARN light comes on

and text appears in the display

area identifying the problem.

Red

ALARM

A fault condition causes the red

alarm light to flash and an alarm

text is displayed.

4.1.5 Operation Keys

Operation keys are found at the bottom of the keypad.

Key

Function

Hand

Press to start the drive in local control.

Use the navigation keys to control drive

speed

An external stop signal by control input or

serial communication overrides the local hand

Off

Stops the motor but does not remove power to

the drive.

Auto

Puts the system in remote operational mode.

Responds to an external start command by

control terminals or serial communication

Speed reference is from an external source

Reset

Resets the drive manually after a fault has been

cleared.

4.2 Back Up and Copying Parameter

Settings

Programming data is stored internally in the drive.

The data can be up loaded into the keypad
memory as a storage back up

Once stored in the keypad, the data can be
downloaded back into the drive

Or downloaded into other frequency converters
by connecting the keypad into those units and
downloading the stored settings. (This is a quick
way to program multiple units with the same
settings.)

Initialisation of the drive to restore factory default
settings does not change data stored in the
keypad memory

WARNING

UNINTENDED START!

When drive is connected to AC mains, the motor may start
at any time. The drive, motor, and any driven equipment
must be in operational readiness. Failure to be in
operational readiness when the drive is connected to AC
mains could result in death, serious injury, equipment, or
property damage.

User Interface

AF-600 FP Operating Instructions

26