GE Industrial Solutions ASTAT XT User Manual

Page 12

Advertising
background image

12

• Technical Specifications

Phase Loss, Under/over
Frequency:

Trips when one or two phases are missing, or frequency is < 40Hz or > 65Hz.
Optional auto reset.

Phase Sequence:

Trips when phase sequence is wrong

Long Slow Speed Time:

Trips if operating at slow speed TRQ for more than 1-30 sec (1-250 sec

9

)

Wrong Connection:

Prevents starting, trips if motor is not connected / incorrectly connected to the
ASTAT-XT (not active in D.Set: Generator Parameters)

Shorted SCR:

Trips if one or more SCRs have been shorted
(not active in D.Set: Generator Parameters)

Heat Sink Over
Temperature:

Trips when heat-sink temperature rises above 85°C

External Fault:

Trips when an external contact closes for 2 sec.

Motor Thermistor:

Trip level setting 1-10KΩ, trips when resistance decreases below the level set

Control:
Displays:

LCD in 4 – Field selectable languages and 8 LEDs

Keypad:

6 keys for easy setting

Aux Contact – Immediate:

1 C/O, 8A, 250VAC, 2000VA

Aux Contact – End Of
Ramp:

1 C/O, 8A, 250VAC, 2000VA

Fault Contact:

1 C/O, 8A, 250VAC, 2000VA

Communication:

RS 485 with Modbus protocol for full control and supervision

Communication (optional): Profibus DPV1 for full control and supervision
Communication (optional): DeviceNet

tm

for full control and supervision

Temperatures Operating:

-10° to 50°C

Storage:

-20° to 70°C

Standards:
Dielectric Test:

2500VAC

Degree of Protection:

IP 20 for QTx0008 - QTx0072 ; IP 00 for QTx0085 – QTx1400

Pollution Degree:

3

EMC Emissions:

EN 61000-6-4 CISPR 11 Class A

Immunity:

EN 61000-6-2 ESD 8KV air, IEC 801-2;
Electric RF field 10 V/m, 20-1000Mhz, IEC 801-3
Fast transients 2KV, IEC 801-4

Safety:

EN IEC 600947-4-2 and EN IEC 60947-1 Related to safety requirements.
UL508C

Rated Operational Current

AC:53a:4-30: 50-4

Normal Service Conditions:
Altitude:

Up to 1000m.

Humidity:

95% at 50°C or 98% at 45˚C

Fan and Control Consumption Ratings:
QTx0008 to QTx0031

: No fan

Total approximate consumption:

150VA

QTx0044 to QTx0072

: Fan 35 VA

Total approximate consumption

185VA

QTx0085 to QTx0170

:Fan 60 VA

Total approximate consumption

210VA

QTx0210 to QTx0390

: Fans 105 VA (35VA x 3)

Total approximate consumption

255VA

QTx0460 to QTx1400A

: Fans 150 VA (50VA x 3)

Total approximate consumption

300VA

Advertising