• Control Keypad


4.2

Push-Buttons

Mode

Scrolls through the display and programming menus of the ASTAT-XT.

14

Select

When a mode name is displayed, pressing this button drills down to the parameters for that mode.
When a parameter is displayed, pressing this button scrolls to the next parameter.

Allows the operator to increment adjusted values shown in the display. Operator should press this
button once to increment one value, or continuously to rapidly increment values up to the maximum
value.

Allows the operator to decrement adjusted values shown in the display. Operator should press this
button once to decrement one value, or continuously to rapidly decrement values up to the minimum
value.

Set

Stores modified parameters only when you have scrolled through all parameters and Store
Settings Xxxxxx Parameters

is displayed. After you store a parameter successfully Data

Saved OK

will display.

15

Reset

Resets the ASTAT-XT after a fault has been dealt with and the start command has been removed. This
cancels the fault displayed and allows you to restart the motor.


4.3

Status LEDs

Green On

Lights when the control supply voltage is connected to the ASTAT-XT.

Yellow Start

Lights during soft start, indicating that motor supply voltage is ramping up.

Green Run

Lights after completion of the starting process, indicating that motor is receiving
full voltage. This LED flashes during slow speed operation.

Yellow Soft Stop

Lights during soft stop, indicating that the motor supply voltage is ramping down.

Red

Stop

Lights when the motor is stopped.

Yellow

Save/Slow
Speed

Lights when Energy Saving is in operation.
Flashes when the motor is running in Slow Speed.

Green

Dual
set/Reverse

Lights when Dual Settings is in operation.
Flashes when the motor is running in Slow SP Reverse.

Red

Fault

Lights upon operation of any of the built-in protections.

4.4

Reviewing and Modifying Parameters

Press the Mode key several times until you reach the required mode page.
Press the Select key to review parameters for this mode.

Once you reach the required parameter, use the ▼ or ▲ keys to modify its value.
To store the new parameters, press the Select key until the Store Settings Xxxxxx Parameters message
displays and then press the Set key. The Data Saved OK message will display for 2 seconds.
Note:
After completing parameter settings:

Turn control voltage OFF

Wait 3 seconds

Reconnect control voltage

14

Pressing Mode continuously increases the speed at which the parameters change.

15

Pressing the Set button at any other time has no effect.