Marker to (–>) Menu

The Marker To (–>) menu lets you perform the following actions:

Modulation

Measurements

When in the WCDMA measurement mode with the Code Domain Power/Error graph
type selected, the following marker selections are available (Refer to the WCDMA Graph
Type Dialog on page 4-48 for
information on setting graph types):

Active Marker: To select the active marker, press on the Active Marker field and select a
marker from the fly-out menu.

To turn the active marker on or off, press the Off/On button.

Delta Markers are not available.

Marker n(Code@SF): Set the Code Number@ Spreading Factor by pressing in the
Marker n(Code@SF) parameter field (where n is the active marker’s number) and
entering a value using the numeric keys. When a new value is entered, the terminator
fly-out will appear with Enter or Cancel. Press on the Spreading Factor button and select
the spreading factor from the menu fly-out. The rotary knob or Up/down arrow keys may
also be used to increment the marker value.

The marker’s value is displayed in the field below Marker n(Code@SF) and on the
graticule display.

All Markers Off: Press the All Markers Off button to deactivate all of the markers.

Uplink Branch: Press the I/Q toggle button to select between the I or Q channel of the
WCDMA Uplink mode. This button is only available when in the Uplink mode.

Note: Marker selections in the WiMAX measurement mode are made via the WiMAX application. Refer to the

Signature™ Option 41 SignalLab WiMAX Analysis Software User Guide, part number: 10410-00276 for
information on WiMAX measurements using Signature.

Table 4-10. Marker To (–>) Menu

Marker selections are made available depending on the measurement mode and graph
type selected.

Mkr->Peak: To send the marker to the trace peak, press on the Mkr->Peak button. The
peak is on the active trace when this menu is accessed and the enter key may be used
to quickly send the active marker to the trace peak.

Next Peak: To send the marker to the next trace peak, press on the Next Peak button.

CF = Mkr: To change the center frequency to the current marker frequency value, press
on the CF = Mkr button.

RL = Mkr: To change the reference level to the current marker value, press on the
RL = Mkr button.

Mkr->Min: To send the marker to the trace minimum, press on the Mkr->Min button.