Measuring a pulse in the time domain, Measuring a pulse in the time domain -24 – Anritsu Series MS278XB User Manual

Page 180

Advertising
background image

Measurement Examples

Measurements

5-24

MS278XB OM

Measuring a Pulse in the Time Domain

The following example shows a triggered measurement of a pulsed 1 GHz signal in zero-span mode:

1. Preset the analyzer using the Preset button.
2. On the analyzer, set up the following:

Center Frequency: 1 GHz
Span: 0 Hz
Reference Level: 10 dBm

3. On the Bandwidth menu, set the sweep time to be twice the pulse width of the signal. In this case, it is set

to 0.2 ms to measure a 0.1 ms pulse width.

4. On the Trigger menu, set the trigger source to Video, enter a trigger level of –20 dBm, and ensure that

Rising edge triggering is selected.

The display should look like the one in the figure below:

Figure 5-5.

Measuring a Pulse in the Time Domain