Anritsu Series MS278XB User Manual

Page 95

Advertising
background image

Instrument Overview

Rear Panel and Connector Diagrams

MS278XB OM

3-43

Table 3-10. Index 6: IEEE 488.2 GPIB Connector Pinout Diagram

Pin

Name

Description

1-4

DIO 1 through DIO 4

Data Input/Output. Bits are HIGH when the data is logical 0 and LOW when the
data is logical 1.

5

EOI

End or Identify. A low-true state indicates that the last byte of a multi byte
message has been placed on the line.

6

DAV

Data Valid. A low-true state indicates that the talker has (1) sensed that NRFD
is LOW, (2) placed a byte of data on the bus, and (3) waited an appropriate
length of time for the data to settle.

7

NRFD

Not Ready For Data. A high-true state indicates that valid data has not yet
been accepted by a listener.

8

NDAC

Not Data Accepted. A low-true state indicates that the current data byte has
been accepted for internal processing by a listener.

9

IFC

Interface Clear. A low-true state places all bus instruments in a known state—
such as, unaddressed to talk, unaddressed to listen, and service request idle.

10

SRQ

Service Request. A low-true state indicates that a bus instrument needs
service from the controller.

11

ATN

Attention. A low-true state enables the controller to respond to both its own
listen/talk address and to appropriate interface messages—such as, device
clear and serial poll.

12

Shield

Ground Point.

13-16

DIO 5 through DIO 8

Data Input/Output. Bits are high with the data is logical 0 and LOW when the
data is logical 1.

17

REN

Remote Enable. A low-true state enables bus instruments to be operated
remotely, when addressed.

18 to
24

GND

Logic ground.

Advertising