Tpc limit edge definition dialog, Tpc limit edge definition dialog -54 – Anritsu Series MS278XB User Manual

Page 152

Advertising
background image

Parameter Entry and Measurement Setup Dialog Archive

Front Panel Menus

4-54

MS278XB OM

TPC Limit Edge Definition Dialog

The TPC Limit Edge Definition dialog lets you manually enter the transmit power control limit edge
definitions.

TPC Config Tab

Time Range: Enter the number of frames for the
time range.

Averaging Time/Slot: Enter the average time per
slot.

TPC Limit Check: Select transmit power control
limit check On or Off.

Limits: Sets the TPC limits edge definitions.
Refer to Figure 4-22 for more information on
setting the TPC limit edge definitions.

Step Size: Select step sizes of 1, 2 or 3 dB.

Command Pattern: Select the command pattern
of –1, 0 or 1.

TPC Test Profile: Only Uniform is available at this
time.

Custom Profile Name: Not available at this time.

Base Station/User Equipment: Uplink or
Downlink.

For each step size option, both the upper and
lower limit can be set for the command patterns of
1, 0, and –1

Figure 4-22. TPC Limit Edge Definition Dialog

Figure 4-21. WCDMA Setup Dialog