Appendix G Device Diagnostic

C O D E S

150

PowerSmart+ Advanced Power Quality Meter

Appendix G Device Diagnostic Codes

Diagnostic
Code

Description

Reason

2

Memory/Data fault

Hardware failure

3

Hardware watchdog
reset

Hardware failure

5

CPU exception

Hardware failure

6

Run-time software error

Hardware failure

7

Software watchdog
timeout

Hardware failure

8

Power Down/Up

Normal power-up sequence

9

Warm restart

External restart via
communications or by firmware
upgrade

10

Configuration reset

Corrupted setup data has been
replaced with the default
configuration

11

RTC fault

The clock time has been lost

13

Low battery

Battery replacement is required.
With auto-reset.

15

EEPROM fault

Hardware failure

See

Device Diagnostics

in Chapter 4 for more information on the PowerSmart+ Advanced