GW Instek PSW-Series Programming & Command manual User Manual

Page 25

Advertising
background image

GETTING STARTED

25

Falling current slew rate F-07

0.01A/s~72.00A/s (PSW 30-36)
0.1A/s~144.0A/s (PSW 30-72)
0.1A/s~216.0A/s (PSW 30-108)
0.01A/s~27.00A/s (PSW 80-13.5)
0.01A/s~54.00A/s (PSW 80-27)
0.01A/s~81.00A/s (PSW 80-40.5)
0.01A/s~14.40A/s (PSW 160-7.2)
0.01A/s~28.80A/s (PSW 160-14.4)
0.01A/s~43.20A/s (PSW 160-21.6)
0.001A/s ~ 9.000A/s (PSW 250-4.5)
0.01A/s ~ 18.00A/s (PSW 250-9)
0.01A/s ~ 27.00A/s (PSW 250-13.5)
0.001A/s ~ 2.880A/s (PSW 800-1.44)
0.001A/s ~ 5.760A/s (PSW 800-2.88)
0.001A/s ~ 8.640A/s (PSW 800-4.32)

Internal resistance
setting

F-08

0.000Ω~0.833Ω (PSW 30-36)
0.000Ω~0.417Ω (PSW 30-72)
0.000Ω~0.278Ω (PSW 30-108)
0.000Ω~5.926Ω (PSW 80-13.5)
0.000Ω~2.963Ω (PSW 80-27)
0.000Ω~1.975Ω (PSW 80-40.5)
0.000Ω~22.222Ω (PSW 160-7.2)
0.000Ω~11.111Ω (PSW 160-14.4)
0.000Ω~7.407Ω (PSW 160-21.6)
0.00Ω ~ 55.55Ω (PSW 250-4.5)
0.00Ω ~ 27.77Ω (PSW 250-9)
0.00Ω ~ 18.51Ω (PSW 250-13.5)
0.0Ω ~ 555.5Ω (PSW 800-1.44)
0.0Ω ~ 277.8Ω (PSW 800-2.88)
0.0Ω ~ 185.1Ω (PSW 800-4.32)

Bleeder circuit control

F-09

0 = OFF, 1 = ON

Buzzer ON/OFF control F-10

0 = OFF, 1 = ON

Measurement Average
Setting

F-17

0 = Low, 1 = Middle, 2 = High

Lock Mode

F-19

0 = Panel lock: allow output off
1 = Panel lock: allow output on/off

USB/GPIB settings
Front panel USB State

F-20

0 = Absent, 1 = Mass Storage

Rear panel USB State

F-21

0 = Absent, 2 = USB-CDC, 3 = GPIB-
USB adapter