PSW Series Programming Manual

80

OFF

Turns the buzzer off.

1

<NR1> Turns the buzzer on.

ON

Turns the buzzer on.

Return parameter <Boolean>

Returns the buzzer status.

SYSTem:CONFigure:BLEeder[:STATe]

Set

Query

Description

Sets or queries the status of the bleeder resistor.

Syntax
Query Syntax

SYSTem:CONFigure:BLEeder[:STATe] {OFF|ON|0|1}
SYSTem:CONFigure:BLEeder[:STATe]?

Parameter

0

<NR1> Turns the bleeder resistor off.

OFF

Turns the bleeder resistor off.

1

<NR1> Turns the bleeder resistor on.

ON

Turns the bleeder resistor on.

Return parameter <Boolean>

Returns bleeder resistor status.

SYSTem:CONFigure:BTRip[:IMMediate]

Set

Description

Trips the power switch trip (circuit breaker) to
turn the unit off (shut down the power).

Syntax

SYSTem:CONFigure:BTRip[:IMMediate]

SYSTem:CONFigure:BTRip:PROTection

Set

Query

Description

Enables/Disables the power switch trip (circuit
breaker) when the OVP or OCP protection settings
are tripped. This setting only applies after power
has been reset.

Syntax

SYSTem:CONFigure:BTRip:PROTection {OFF|ON|0|1}

Query Syntax

SYSTem:CONFigure:BTRip:PROTection?

Parameter

0

<NR1> Disables the power switch trip for
OVP or OCP.

OFF

Disables the power switch trip for OVP or
OCP.

1

<NR1> Enables the power switch trip for
OVP or OCP.