Display commands, Display:menu[:name – GW Instek PSW-Series Programming & Command manual User Manual

Page 56

Advertising
background image

PSW Series Programming Manual

56

Parameter

<voltage>

<NRf> 0% ~ 105% of the rated output
voltage.

<current>

<NRf> 0% ~ 105% of the rated output
current.

MIN

0 volts/0 amps

MAX

Maxium value for the present range.

Return parameter <NRf>

Returns the voltage and current.

Example

APPL 5.05,1.1
Sets the voltage and current to 5.05V and 1.1A.

Query Example

APPL?
+5.050, +1.100
Returns voltage (5.05V) and current (1.1A) setting.

Display Commands

DISPlay:MENU[:NAME] .................................................... 56

DISPlay[:WINDow]:TEXT:CLEar ..................................... 57

DISPlay[:WINDow]:TEXT[:DATA] .................................. 57

DISPlay:BLINk ...................................................................... 57

DISPlay:MENU[:NAME]

Set

Query

Description

The DISPlay MENU command selects a screen
menu or queries the current screen menu.

Syntax
Query Sytax

DISPlay:MENU[:NAME] <NR1>
DISPlay:MENU[:NAME]?

Parameter/
Return parameter

<NR1>

Description

0

Measurement-Voltage / Measurement-
Current

1

Measurement-Voltage / Measurement-Power

2

Measurement-Power / Measurement-Current

3

Set Menu

4

OVP / OCP Menu

5~99

Not Used.

100~199

F-00~99 Menu.

Advertising