27

Show Version

F-89

0, 1 = PSW version
2, 3 = PSW build year
4, 5 = PSW build month/day
6, 7 = Keyboard CPLD version
8, 9 = Analog-Control CPLD version
A, B = Reserved
C, D = Kernel build year
E, F = Kernel build month/day
G, H = Test command version
I, J = Test command build year
K, L = Test command build
month/day

M, N

=

USB Driver version.

Power On Configuration Settings*


CV Control

F-90

0 = Panel control (local)
1 = External voltage control
2 = External resistance control

(Ext-R 10kΩ = Vo, max)

3 = External resistance control

(Ext-R

10kΩ = 0)

CC Control

F-91

0 = Panel control (local)
1 = External voltage control
2 = External resistance control

(Ext-R 10kΩ = Io,max)

3 = External resistance control

(Ext-R

10kΩ = 0)

Power-ON Output

F-92

0 = OFF at startup
1 = ON at startup
T001 ~ T010 = Run test script TXX at
start up

Master/Slave

F-93

0 = Master/Local
1 = Master/Parallel1
2 = Master/Parallel2
3 = Slave/Parallel
4 = Slave/Series (Only 30V, 80V, 160V
models)

External Out Logic

F-94

0 = High ON, 1 = Low ON

Power Switch trip

F-95

0 = Enable , 1 = Disable

Calibration Settings*
Calibration

F-00

0000 ~ 9999